Description
Here are the full specifications and details provided by AFL company:
Parameter | Value |
Dielectric Strength | Minimum 2500 Vrms for 1 minute |
Torque (mounting bosses) | 20 in./lbs. |
High Temperature Storage/Mold Stress °F (°C) | 14 days at 159 (70.55) |
Temperature Cycling with Humidity °F (°C) | 150 day cycling from 40 to 140 (4.44 to 60) with 95% RH |
Impact Test °F (°C) | -40 (-40), 5 ft./lbs. on all external surfaces |
Drop Test °F (°C) | -40 (-40), 5 ft. (152.4 cm) onto concrete surface 4 times |
Rain | 24 hours at 10 psi |
UV Resistance (Days Exposed) | 60 per ASTM-G26-84 |
Salt Fog (Days Exposed) | 60 per ASTM-BLL7-90 |
Flammability | UL94-5V |
Chemical Resistance | 30 Days at 100°F and 95% RH Resists chipping and/or cracking when subject to: house paint, wasp spray, sulfuric acid, kerosene and sodium hydroxide |
Material | ULlisted flame retardant thermoplastic alloy |
Dimensions (H x W x D) in. (cm) | 13.0″ x 9.0″ x 3.0″ |
Cable Entrances in. (cm) diameter – Output | 8 x 0.500 (1.2) |
Cable Entrances in. (cm) diameter – Input | 2 x 0.625 (1.5), 1 x 0.250 (0.6) (ground wire) |
Covers | Molded-in snap finger and or 3/8″ hex head fastener and F term |
Reviews